Disconnecting Inputs from Outputs

To undo routing, click the junction again to disconnect the receiver from the transmitter.
NOTE: After making changes to Dante network routing such as subscriptions, device
names, or channel labels, wait at least 5 seconds before disconnecting or powering
down the devices. This ensures that the new information is properly saved to those
devices. Device level configuration such as sample rates, latency, and clock settings
are saved instantly.

Sending SIS Commands to Dante Audio Interface Devices through the XMP

The XMP 240 C AT can be set to pass through SIS commands to connected Dante-
controlled Extron devices (see
of SIS commands).
To send an SIS command to an AXI device connected to a XMP 240 C AT:
1.
Connect the XMP 240 and Dante-controlled devices to the same network via their AT
ports (see
2.
Connect to the XMP 240 via the DataViewer or HyperTerminal utility (see
Communication and Control
3.
Use the Set verbose mode command to set the XMP 240 to Verbose mode 3 (see
Set verbose mode
Example:
Command
w3cv|
4.
Use the Query available remote devices command (see
devices
the XMP.
Example:
Command
waexpr|
NOTE: This list is similar to the list displayed within Dante Controller.
5.
Use the Enable remote connection command to display the remote Dante-controlled
device responses based on the list of devices provided in the response in step 4 (see
Enable remote connection for listening
desired devices.
Example:
Command
wcAXI02-XTP-RoomA*1expr|
NOTE: AXI devices can be set up for listening even if not currently connected to the
XMP unit.
6.
To verify that the XMP is listening to the correct remote devices, use the Query remote
devices being listened to command to display a list of all remote devices enable with the
command in step 5 (see
Example:
Command
wlexpr|
Dante Control and Configuration
Physical Dante Network Setup
on page 103).
on page 112).
on page 120) to receive a list of Dante devices that are currently connected to
Query remote devices being listened to
on page 120 for the list
on page 96).
Response
Vrb3
Query available remote
Response
]
ExprA
AXI-XTP-RoomA
]]
AXI-XTP-RoomB
on page 120). Repeat if necessary for all
Response
]
ExprCAXI-XTP-RoomA*1
on page 120).
Response
]
ExprL
AXI-XTP-RoomA
XMP 240 C AT • Dante Controller
Remote