Extron electronics DMP 128 Plus C V AT Setup Manual
Extron electronics DMP 128 Plus C V AT Setup Manual

Extron electronics DMP 128 Plus C V AT Setup Manual

Certified dsp bundle for microsoft teams rooms – extra-large room
Hide thumbs Also See for DMP 128 Plus C V AT:

Advertisement

Extron Certified DSP Bundle for Microsoft
Rooms – Extra-Large Room • Setup Guide
IMPORTANT NOTE:
www.extron.com
Go to
Microsoft Teams and Extron have come together to provide Teams Rooms solutions with our certified hardware. Now it is easier
than ever to stay connected with flexibility of realtime collaboration from anywhere. The products in our Teams Rooms Certified
Design Solutions have been designed and meticulously tested for best-in-class performance and ease of use.
Requirements
Product
DMP 128 Plus C V AT
XPA U 1004 SB
IPCP Pro 255Q xi
SF 26CT LP
RSU 129
SPK14P 14 AWG
USB CFG cable
MLC PW Audio cable
Network cable
Network cable
Network cable
Product
TeamConnect Ceiling Medium
Product
Teams Rooms computer
Network switch
Windows
computer or laptop
®
NOTE:
The Windows computer or laptop is required for adjustments and can be disconnected after system configuration.
for the complete user guide, installation instructions, and specifications.
Extron Equipment List
Description
12x8 Digital Matrix Processor w/ AEC, VoIP, & Dante
Four Channel Bridgeable Output Amp, 100/200 Watts
Control Processor with LinkLicense UI upgrade
6.5" Low profile, 2-way Ceiling Speakers, pair
1U 9.5" Deep Universal Rack Shelf, Gray
Plenum Speaker Cable - 150' (45.7 m)
USB A Male to USB Mini B Male 6' (1.8 m)
Audio patch cable for audio DSP output to amplifier input - 6' (1.8 m)
UTP RJ-45 Cat-5e Plenum network cable - 35' (10.7 m)
UTP RJ-45 Cat-5e Plenum network cable - 50' (15.2 m)
Cat-6 cable non Plenum - 6' (1.8 m)
Sennheiser
Description
Beamforming Ceiling Microphone array
Additional Required Equipment
Description
Teams Rooms computer with camera and control interface
10-port PoE network switch
Computer MUST contain the following:
Extron DSP Configurator
Extron Global Configurator Plus and Professional
Extron Toolbelt
Dante Controller
Sennheiser Control Cockpit
Extron system configuration *.zip files
Equipment List
®
Teams
®
®
Quantity
®
Quantity
Quantity
1
1
1
3
1
1
1
1
1
1
2
2
1
1
1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DMP 128 Plus C V AT and is the answer not in the manual?

Questions and answers

Summary of Contents for Extron electronics DMP 128 Plus C V AT

  • Page 1 Design Solutions have been designed and meticulously tested for best-in-class performance and ease of use. Requirements Extron Equipment List Product Description Quantity DMP 128 Plus C V AT 12x8 Digital Matrix Processor w/ AEC, VoIP, & Dante ® XPA U 1004 SB Four Channel Bridgeable Output Amp, 100/200 Watts IPCP Pro 255Q xi...
  • Page 2 Dante (PRI) 3 Computer Control Processor (OFE) LAN/VoIP 1 Extron XPA U 1004 SB Amplifier Extron DMP 128 Plus C V AT Audio DSP Processor Audio Output 1 SPEAKER Out 1 OFE – Owner Furnished Equipment (not included in package) Video Audio...
  • Page 3: Installation Details

    Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Installation Details Audio Cables See figure 2 for the connections needed between the DMP Plus and the XPA U amplifier. Use the supplied balanced audio cable to connect each product.
  • Page 4 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Sennheiser TeamConnect Ceiling Medium Setup Sennheiser TeamConnect Ceiling Medium A single network cable connection from the Sennheiser TeamConnect Ceiling Medium (TCC M) to the network switch supports PoE into the microphone, Dante audio, and LED feedback for call and mute status.
  • Page 5 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Setting Up Third-party Access Figure 6. Setting up Third-party Access Select the Access tab to enable 3rd Party Access and configure a 3rd party Password. Document the 3rd party password for the device.
  • Page 6 NOTE: The DMP 128 Plus C V AT and TCC M Dante connections are set to DHCP by default. If they cannot be discovered, ensure the correct interface is selected on the PC by selecting Interfaces from the File menu.
  • Page 7 Click the first channel name and rename it TCCM Ref. Figure 11. Transmit Tab of DMP Plus Device View Select the Device Config tab and rename the DMP 128 Plus C V AT as desired. Click Apply. Figure 12. Device Config Tab of DMP Plus Device View From the Device View drop-down menu, choose one of the TCC M devices (see figure 13, 10.
  • Page 8 • The FarEndOut transmitter channels of the TCC M devices should be routed to the first two receiver channels of the DMP 128 Plus C V AT. A check mark at the intersection indicates the subscription is made. A check mark also appears next to the receive channel.
  • Page 9 Setup Guide Extron DMP 128 Plus C V AT Setup To configure the Extron DMP 128 Plus C V AT, perform these steps: Set IP address via embedded web page. Set the computer or laptop IP address within the range of the product IP address. The default settings are (LAN for non-V models, LAN 1 for V models): •...
  • Page 10 Open the Extron DSP Template file (downloaded previously in .zip file) with DSP Configurator software. Connect to a DMP 128 Plus C V AT in Live Mode by clicking the Live button in the menu bar of DSP Configurator (see figure 18, ).
  • Page 11 Synchronize with Device Dialog Screen Click OK. Once the push is completed, the current state of the connected DMP 128 Plus C V AT is displayed in the DSP Configurator status panel and the device is ready for further configuration.
  • Page 12: Get Ready

    Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Extron IPCP Pro 255Q xi Setup The Control Procesor in this system facilitates the communication between the Extron DMP Plus and Sennheiser TCC M. Get Ready Download and install the latest version of the following software: •...
  • Page 13 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Set Up the Control Processor for Network Communication. Connect the PC to be used for setup and the LAN (or AV LAN) port of the control processor to the same Ethernet network. Start Toolbelt and use it to discover the IPCP Pro 255Q xi: Figure 21.
  • Page 14 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Set the DHCP status, IP address, subnet, gateway IP address, and related settings. Figure 24. Configure Network Settings NOTES: • When setting up DHCP during network configuration or if using a host name instead of an IP address, the user must enter a qualified host name (Username.HostName.Domain).
  • Page 15 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Configure or Program the Control Processor NOTE: See the Global Configurator Plus and Professional Help File as needed for step-by-step instructions and detailed information. The help file for GCP includes an introduction to the software and how to start a project and configuration. Using Global Configurator, configure the control processor.
  • Page 16 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide figure Choose DMP Plus under the Ethernet Ports list (see , on page 15). Set IP address ( ) and Admin password of the DMP Plus device ( Figure 28.
  • Page 17 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Test and Troubleshoot Test the system (see the IPCP Pro Q xi and xi Series User Guide for an outline of the system testing procedure). Make adjustments to wiring or configuration as needed.
  • Page 18: Troubleshooting

    Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Troubleshooting DMP Plus Acoustic Echo Cancellation (AEC) AEC Setup Overview Proper gain structure involves the relationship between the signal at the selected reference and the signal at the mic input, within the context of proper levels for the reference and mic inputs independently.
  • Page 19: Technical Support

    Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide Technical Support For Extron technical support, visit: www.extron.com/company/contactus.aspx. For Sennheiser technical support, visit: sennheiser.com/service-support.
  • Page 20 Extron Certified DSP Bundle for Microsoft Teams Rooms – Extra-Large Room • ® ® Setup Guide For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the Extron Safety and Regulatory Compliance Guide on the Extron website. www.extron.com ©...

Table of Contents