  • Page 1 DMP Plus Series / C V Models DMP Plus Series / C V AT Models Patton POTS Configuration Guide REVISION: 1.0.0 DATE: OCTOBER 16, 2020...
  • Page 2 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Revision Log Date Version Notes Oct 16, 2020 1.0.0 Initial Release Page 2 of 28...
  • Page 3: Table Of Contents

    1.1.4 Patton POTS interface ....................6 1.1.5 Wiring ........................6 Configuring Patton POTS interface for DMP Plus Series C V (AT) VoIP ....... 7 Ordering Information ....................... 7 2.1.1 Patton SN4112/JO/EUI - VoIP Gateway 2 FXO Ports ..........7 2.1.2 Firmware used during testing: R6.11 2019-07-02 ...........
  • Page 4 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix A: Configuration Files – Attached to PDF ..............21 Appendix B: How to manually set the IP address of the Patton SN4112 ........22 Appendix C: How to import configuration into DMP Plus ............
  • Page 5: Introduction

    DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 1.0 Introduction This document provides essential instructions for configuring the VoIP lines of DMP Plus Series, C V and C V AT models, with the Patton SN 4110 Series FXO. DMP Plus Relates to the following products: •...
  • Page 6: Patton Pots Interface

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 1.1.3 Patton POTS interface • LAN port • IP Address: 192.168.1.253 / 255.255.255.0 • Firmware: R6.11 2019-07-02 1.1.4 Wiring • Using a CAT5/6 network cable...
  • Page 7: Configuring Patton Pots Interface For Dmp Plus Series C V (At) Voip

    DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 2.0 Configuring Patton POTS interface for DMP Plus Series C V (AT) VoIP This section will guide you through the setup of the Patton POTS interface. 2.1 Ordering Information The Patton Smart Node VoIP Gateway has multiple different models.
  • Page 8 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 • Using Extron DataViewer connect to the Patton POTS interface via RS-232 o Download the attached file “DataViewer Set Patton IP address.txt” from the PDF ...
  • Page 9: Upload Configuration Into Patton Pots Interface

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 2.3 Upload configuration into Patton POTS interface After the IP address has been setup on the Patton POTS interface, the attached configuration file must be uploaded via the webpage interface.
  • Page 10 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 • Select Import Firmware • Follow the instructions below o Shutdown VoIP Gateways o Firmware upload o Once the VoIP Gateways are shut down the Download firmware dialog will appear o Select “Choose file”...
  • Page 11: Upload Configuration File

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 2.4 Upload configuration File • If the firmware has been updated, verify the unit has been restarted • From the Patton webpage Select Import/Export, Upper Left corner •...
  • Page 12: To Restart / Reload, Select Reload In The Lower Left

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 2.4.1 To restart / reload, select Reload in the lower left 2.4.2 If any changes are made, they will need to be saved to the startup-config ...
  • Page 13: Adjust Auto Hang-Up / Call Disconnection

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 2.5 Adjust auto hang-up / Call disconnection If the calls do not disconnect from the POTS line, the Disconnect signals may need to be adjusted. The screen below is configured for Loop Break 2.5.1 Adjust auto hang-up and Call disconnection if necessary...
  • Page 14: Configuring Dmp Plus Series C V (At) Voip Lines

    3.0 Configuring DMP Plus Series C V (AT) VoIP Lines VoIP configuration of the DMP Plus Series is handled exclusively through a web interface, served from the device itself. The VoIP landing page is accessed through an address of the format - http://192.168.254.254/www/voip.html...
  • Page 15 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 5. Under VoIP Interface select LAN 2 a. The Default VoIP interface is LAN 1 and will need to be set to LAN 2 6. Under the LAN 2 Network interface: a.
  • Page 16: Transport Configuration

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 3.2 Transport Configuration Click on the Transport tab to access signaling transport configuration. Check that the transport is set to UDP. In the event that changes need to be made, click Apply to commit any adjustments to the device.
  • Page 17: Line Registration

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 3.3 Line Registration Click on the Line 1 tab to be configured as part of the system. 1001 1) User Name: 2) Authentication Name: 1001...
  • Page 18: Codecs

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 3.4 Codecs The availability and priority of codecs may be changed from within the Audio tab. Codecs will only be available for use within phone calls if they are moved from the Available to the Assigned column.
  • Page 19: Dialing

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 3.5 Dialing Use the Dialing tab to select Out of Band – RFC 2833 for the Patton POTS interface. Click Apply after selecting Out of Band – RFC 2833 DTMF signaling method for the line.
  • Page 20: System Overview

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 3.6 System Overview The Home tab is used to view a summary of Line configuration and call status. In the example below, Line 1 has a configuration but shows as not registered.
  • Page 21: Appendix A: Configuration Files - Attached To Pdf

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix A: Configuration Files – Attached to PDF If needed, the configuration file “voipConfig.conf” is attached to the PDF • To access the file select “Attachments”...
  • Page 22: Appendix B: How To Manually Set The Ip Address Of The Patton Sn4112

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix B: How to manually set the IP address of the Patton SN4112 Login Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to display.
  • Page 23: Appendix C: How To Import Configuration Into Dmp Plus

    DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix C: How to import configuration into DMP Plus 1. Navigate to the DMP Plus Series VoIP configuration webpage and click on the System tab. 2. Under Import System Configuration, click the Browse button to locate the voipConfig.conf file attached to this PDF...
  • Page 24: Appendix D: Patton Rs-232 Cable Wiring Detail

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix D: Patton RS-232 Cable wiring detail The Patton POTS interface come with a RJ-45 to DB-9 RS-232 cable, Patton Model 16F-894 Below is the wiring detail for the cable:...
  • Page 25: Appendix E: Copy Of Dmp Plus Voip Configuration

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix E: Copy of DMP Plus VoIP Configuration {"network":{"voip_interface":2,"vlan_id":0,"dhcp_mode":0,"ip_add r":"192.168.1.254","netmask":"255.255.255.0","gateway":"0.0.0.0" ,"dns1":"","dns2":"","pcp":3,"dscp_sip":24,"dscp_rtp":46,"lldp_m ed_enabled":0,"lldp_vlan_id_enabled":1,"lldp_pcp_enabled":1,"lld p_dscp_enabled":1,"lldp_location_enabled":1,"lldp_inventory_enab led":0,"street":"","building":"","city":"","state":"","zip":""," country":"","device_id":"","local_mode":"default","user_local_ce rt_file":"","user_local_key_file":"","server_certs":[],"server_c as":[],"tls_mode":"alwaysallow","sip_transport":"udp","sipport": 5060,"srtprequire":false,"rtcpenable":true,"reg_default_time":36 00,"registration_fail_retry_count":0,"registration_fail_retry_de lay":600,"rtpstartport":50000,"rtpendport":50999,"sipkeepaliveen abled":true,"sip_outgoing_termination_use_cancel_enable":false," sip_outbound_as_route_enable":true,"sip_reject_username_account_ destination_mismatch":false,"sip_local_port_increased_for_users_ enable":true,"single_codec_mode":"inactive","natmode":"disable", "stunserveripaddress":"","stunserverport":- 1,"turnserveripaddress":"","turnserverport":-...
  • Page 26: Appendix F: Copy Of Patton Configuration

    Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 Appendix F: Copy of Patton configuration #----------------------------------------------------------------# # SN4112/JO/EUI # R6.11 2019-07-02 H323 SIP FXS FXO # 2020-09-30T09:57:04 # SN/00xxxxxxxxxx # Generated configuration file #----------------------------------------------------------------# cli version 3.20...
  • Page 27 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 method 1 local method 2 none context ip router interface eth0 ipaddress 192.168.1.253 255.255.255.0 tcp adjust-mss rx mtu tcp adjust-mss tx mtu context ip router route 0.0.0.0 0.0.0.0 192.168.1.1 1...
  • Page 28 Revision Date: DMP Plus Series C V / C V AT – Patton POTS 10/16/2020 drop-cause user-busy drop-cause destination-out-of-order route call 1 dest-interface IF_FXO_00 route call 2 dest-interface IF_FXO_01 context cs switch no shutdown context sip-gateway GW_SIP interface IF_GWSIP bind interface eth0 context router port 5060...