Command
Digital I/O
Get input status
Get output status
NOTE: Variables shown in the table above, but not listed at the bottom of this page, are listed on the next page.
NOTES:
X5@
=
Digital I/O Channel
X5#
=
Action Type
X5$
=
Varies according to action
type
ASCII command
(host to device)
EX5@
}
GPIT
E X5@
X5%
}
*
GPOT
1 through
= No action/off
0
Mutes
= Level trigger (low mutes)
1
= Level trigger (high mutes)
2
= Edge trigger (high to low mutes, low to high unmutes)
3
= Edge trigger (high to low unmutes, low to high mutes)
4
= Toggle trigger (high to low toggles mute)
5
= Toggle trigger (low to high toggles mute)
6
Group Mutes
= Level trigger (low mutes)
7
= Level trigger (high mutes)
8
= Edge trigger (high to low mutes, low to high unmutes)
9
= Edge trigger (high to low unmutes, low to high mutes)
10
= Toggle trigger (high to low toggles mute)
11
= Toggle trigger (low to high toggles mute)
12
Macros
= Edge trigger (high to low starts macro)
13
= Edge trigger (low to high starts macro)
14
Presets
= Edge trigger (high to low recalls preset)
15
= Edge trigger (low to high recalls preset)
16
Mutes
Input number for muting. If
the input with the corresponding I/O channel number.
Group Mutes
Group member for muting. If
the group with the corresponding I/O channel number.
Macros
Macro number. If
to the corresponding I/O channel number.
Presets
Preset number. If
to the corresponding I/O channel number.
Response
(device to host)
X5#
X5$]
*
X5%
X5^
X5&]
*
*
8
X5#
is not specified, muting matches
X5#
is not specified, muting matches
X5#
is not specified, the macro number defaults
X5#
is not provided, the preset number defaults
DMP 128 Plus • Remote Control and Configuration