Dynamic Filters Tab
Figure 86.
Feedback Suppressor Dialog Box - Dynamic Filters Tab
Dynamic Filters Tab — Provides access to dynamic filter configuration options.
1
Dynamic Filters List — Displays a list of 15 dynamic feedback suppression filters.
2
As feedback is detected on the virtual return channel, dynamic filters are applied to
suppress feedback with the
Move to Fixed Button — Transfers the dynamic filter along with its current parameters
3
to the
Fixed Filters
the
Dynamic Filters
Clear Button — Clears the dynamic filter and contained parameters.
4
Clear All Button — Clears all dynamic filters and resets the feedback detection and
5
suppression process.
Lock Button — Locks current dynamic filters and prevents more dynamic filters from
6
being applied.
Bypass FBS Button — Bypasses the FBS processor. When the button is red, FBS is
7
bypassed.
Set Defaults Button — Resets parameters on all tabs to their default values and
8
positions.
OK Button — Confirms changes made to the contained parameters and closes the
9
Feedback Suppressor
Cancel Button — Reverts any changes made to the contained parameters back to
¢
their states when the current instance of the
opened and closes the dialog box.
parameter defined in the
Q
tab, allowing parameters to be edited. This frees up a filter slot in
list.
dialog box.
Feedback Suppressor
DMP 128 Plus • DSP Configurator Software
Dynamic Filters Tab
1
Dynamic Filters List
2
Move to Fixed Button
3
Clear Button
4
Clear All Button
5
Lock Button
6
Bypass FBS
7
Set Defaults Button
8
OK Button
9
Cancel Button
¢