Canon imageRUNNER C1335 Series Service Manual page 572

Table of Contents

Advertisement

TESTMODE > FAX > MODEM
V34G3TX
V.34 G3 signal transmission test
Details
To test whether the specified V.34 G3 signal is transmitted.
By closing or opening the DC circuit in accordance with the setting
value, the specific G3 signal pattern is transmitted at the specified
transmission speed and modulation speed by the G3 signal
transmission function (V.34) of the modem.
Check this with the speaker.
A setting value other than 0 is indicated as a 3-digit integer (1st digit:
modulation speed, last 2 digits: transmission speed). A value other
than the specified numerical value is invalid.
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 614
0: OFF
• First digit (Modulation speed/baud rate)
1: 2400 baud, 2: 2743 baud, 3: 2800 baud, 4: 3000 baud, 5: 3200
baud, 6: 3429 baud
• Last 2 digits (Transmission speed)
01: 2400 bps, 02: 4800 bps, 03: 7200 bps, 04: 9600 bps, 05:
12000 bps, 06: 14400 bps, 07: 16800 bps, 08: 19200 bps, 09:
21600 bps, 10: 24000 bps, 11: 26400 bps, 12: 28800 bps, 13:
31200 bps, 14: 33600 bps
Default value
0
8
Service Mode > TESTMODE > FAX > FACULTY
T-8-68
8
Service Mode > TESTMODE > FAX > FACULTY
■ FACULTY
TESTMODE > PRINT
G34800TX
G3 4800 bps signal transmission test
Details
To test whether the G3 signal is transmitted at 4800 bps.
By closing or opening the DC circuit, the specific G3 signal pattern is
transmitted at 4800 bps by the G3 signal transmission function.
Check this with the speaker.
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
DETECT1
Ring detection
Details
To check the ON/OFF state of CI, FC, and hook from the line.
The detection results are displayed on the console (UART).
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CI (Calling Identification): Ring signal
UART (Universal Asynchronous Receiver Transmitter): Console
DETECT2
Calling tone detection test 1
Details
To check calling tone signal and FED.
Set the CML relay to ON and detect the calling tone.
The detection results are displayed on the console (UART).
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CML (Connect Modem to Line) relay: Relay installed at the NCU
(Network Control Unit) Board to switch between the telephone and
fax.
DETECT3
Calling tone detection test 2
Details
To check calling tone signal and FED.
Set the CML relay to OFF and detect the calling tone.
The detection results are displayed on the console (UART).
Adj/set/operate method Enter the setting value, and then press Start key.
Caution
Be sure to set the value back to 0 after the test.
Display/adj/set range
0 to 1
0: OFF, 1: ON
Default value
0
Supplement/memo
CML (Connect Modem to Line) relay: Relay installed at the NCU
(Network Control Unit) Board to switch between the telephone and
fax.
8-133