Canon imageRUNNER C1335 Series Service Manual page 444

Table of Contents

Advertisement

■ ANALOG
COPIER> DISPLAY> ANALOG
TEMP
Display of outside temperature
Details
To display the temperature outside the machine.
This is measured by the Environment Sensor 2 that detects the outside
air.
Use case
When checking the temperature outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 60
Unit
1 deg C
Appropriate target value 20 - 27
HUM
Display of outside humidity
Details
To display the humidity outside the machine.
This is measured by the Environment Sensor 2 that detects the outside
air.
Use case
When checking the humidity outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
5 to 90
Unit
1 %
Appropriate target value 30 - 70
ABS-HUM
Display of outside moisture amount
Details
To display the absolute moisture amount outside the machine.
This is measured by the Environment Sensor 2 that detects the outside
air.
Use case
When checking the moisture amount outside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 g
Appropriate target value 0 - 22
FIX-E
Dspl of Fixing Main Heater temperature
Details
To display the temperature of the Fixing Main Heater detected by the
Main Thermistor 1.
Use case
When checking the temperature of Fixing Main Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
FIX-E2
Dspl Fixing Sub Heater front edge temp
Details
To display the front edge temperature of the Fixing Sub Heater detected
by the Sub Thermistor 1.
Use case
When checking the edge temperature of the Fixing Sub Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
8
Service Mode > COPIER > DISPLAY > ANALOG
8
Service Mode > COPIER > DISPLAY > ANALOG
COPIER> DISPLAY> ANALOG
TEMP2
Display of inside temperature
Details
To display the estimated temperature inside the machine that is
calculated from the outside temperature and elapsed time.
Use case
When checking the estimated temperature inside the machine
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 100
Unit
1 deg C
Appropriate target value Room temperature - Room temperature+15 deg C
Related service mode
COPIER> DISPLAY> ANALOG> TEMP
FIX-E3
Dspl of Fixing Sub Heater rear edge temp
Details
To display the rear edge temperature of the Fixing Sub Heater detected
by the Sub Thermistor 2.
Use case
When checking the edge temperature of the Fixing Sub Heater
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 300
Unit
1 deg C
8-5