Error
Detail
Item
code
Code
E009 0002 Title
Fixing disengagement timeout error
Description Signal of the Fixing Pressure Release Sensor could not be detected
at pressure release operation of the Fixing Pressure Release Cam,
and the operation was not completed within 4 sec from the start of
counterclockwise rotation of the Fixing Motor.
Remedy
[Related parts]
• Fixing Assembly (Unit of replacement: Fixing Assembly)
• Harness between the Fixing Drawer (DR01/J5401) and the DC
Controller PCB (UN04/J134) (Unit of replacement: INTERLOCK
ASSEMBLY)
• Harness between the DC Controller PCB (UN04/J135) and the Fixing
Motor (M04/J5412) (Unit of replacement: CABLE, FIXING DRIVE)
• Harness between the Fixing Drawer (DR01/J5401) and the Fixing
Pressure Release Sensor (PS13/J5403) (Unit of replacement: CABLE,
FIXING ASSEMBLY)
• Fixing Pressure Release Sensor (PS13) (Unit of replacement: PHOTO
INTERRUPTER)
• Fixing Drive Unit (Unit of replacement: FIXING DRIVE ASSEMBLY)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
• Harness between the Low-voltage Power Supply PCB (UN01/J315
and J322) and the DC Controller PCB (UN04/J20 and J22) (Unit of
replacement: CABLE, POWER SUPPLY)
• Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER
SUPPLY ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
E009 0003 Title
Fixing pressure retry error
Description Signal of the Fixing Pressure Release Sensor could not be detected
at pressure application operation of the Fixing Pressure Release Cam,
and the operation was not completed within 3 times from the start of
counterclockwise rotation of the Fixing Motor.
Remedy
[Remedy] Replace the Fixing Assembly. (Unit of replacement: Fixing
Assembly)
E009 0004 Title
Fixing disengagement retry error
Description Signal of the Fixing Pressure Release Sensor could not be detected
at pressure release operation of the Fixing Pressure Release Cam,
and the operation was not completed within 3 times from the start of
counterclockwise rotation of the Fixing Motor.
Remedy
[Remedy] Replace the Fixing Assembly. (Unit of replacement: Fixing
Assembly)
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
Error
Detail
Item
code
Code
E010 0001 Title
Bk Drum_ITB Motor error
Description It did not become the specified speed for 500 consecutive msec although
1000 msec have passed from the startup of the Bk Drum_ITB Motor in the
Main Drive Unit. (The detection timing varies depending on the paper feed
conditions.)
Remedy
[Related parts]
• Main Drive Unit (Unit of replacement: MAIN DRIVE ASSEMBLY)
• Harnesses connecting the Bk Drum_ITB Motor (M02/J5702), the
Relay Connector (8P) and the DC Controller PCB (UN04/J140) (Unit of
replacement: MAIN DRIVE ASSEMBLY)
• Fuse in the Low-voltage Power Supply PCB (UN01/FU14) (Unit of
replacement: POWER SUPPLY ASSEMBLY)
• Bk Drum_ITB Motor (M02) (Unit of replacement: MOTOR, DC)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
• Low-voltage Power Supply PCB (UN01) (Unit of replacement: POWER
SUPPLY ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] It is highly possible that the Bk Drum_ITB Motor is not rotating
due to overload or an electrical trouble. Perform the following in the order
while checking whether the error is cleared.
1. Check whether the gears of the Main Drive Unit can be rotated by hand.
a. If they cannot be rotated, replace the Main Drive Unit.
b. If they can be rotated, check the harnesses from the Bk Drum_ITB
Motor to the DC Controller PCB.
2. Measure the both ends of the fuse in the Low-voltage Power Supply
PCB using a tester.
a. If power is flowing to it (the measurement value is less than 1
ohm),
1. Replace the Bk Drum_ITB Motor.
2. Replace the DC Controller PCB.
b. If the power is not flowing to it (the measurement value is 1 ohm or
higher), replace the Low-voltage Power Supply PCB.
[Reference] Before replacing the DC Controller PCB, back up the
service mode data (approx. 2 min) and restore the backup data after the
replacement so the data may be able to be protected.