COPIER> DISPLAY> HV-STS
2ATVC
Dspl secondary transfer ATVC tgt current
Details
To display the decuple value of the voltage flown to the Secondary
Transfer Outer Roller derived from the secondary transfer ATVC control.
If there is no problem in the result of the control, 3 values are displayed
in ascending order.
As the usage of the Secondary Transfer Outer Roller is extended, the
value decreases.
Use case
When identifying the cause at the occurrence of an image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 2TR-CLR
2ATVC2
Dspl secondary transfer ATVC tgt current
Details
To display the decuple value of the voltage flown to the Secondary
Transfer Outer Roller derived from the secondary transfer ATVC control.
If there is no problem in the result of the control, 3 values are displayed
in ascending order.
As the usage of the Secondary Transfer Outer Roller is extended, the
value decreases.
Use case
When identifying the cause at the occurrence of an image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 2TR-CLR
2ATVC3
Dspl secondary transfer ATVC tgt current
Details
To display the decuple value of the voltage flown to the Secondary
Transfer Outer Roller derived from the secondary transfer ATVC control.
If there is no problem in the result of the control, 3 values are displayed
in ascending order.
As the usage of the Secondary Transfer Outer Roller is extended, the
value decreases.
Use case
When identifying the cause at the occurrence of an image failure
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Unit
1 uA
Appropriate target value 50 - 700
Related service mode
COPIER> FUNCTION> CLEAR> 2TR-CLR
2ATVCENV
Dspl sec trns ATVC abslt moistr cntnt
Details
To display the absolute moisture content at execution of the secondary
transfer ATVC.
Use case
At trouble analysis
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 9999
Unit
0.01 g/m3
Appropriate target value 0 - 4000
8
Service Mode > COPIER > DISPLAY > CCD
T-8-5
8
Service Mode > COPIER > DISPLAY > CCD
■ CCD
COPIER> DISPLAY> CCD
TARGET-B
Shading target value (B)
Details
To display the shading target value of Blue.
Continuous display of 0 (minimum) or 2048 (maximum) is considered
a failure of the White Plate data.
Use case
When the scanned image failure occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 2048
Appropriate target value 512 - 2047
TARGET-G
Shading target value (G)
Details
To display the target value of Green.
Continuous display of 0 (minimum) or 2048 (maximum) is considered
a failure of the White Plate data.
Use case
When the scanned image failure occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 2048
Appropriate target value 512 - 2047
TARGET-R
Shading target value (R)
Details
To display the shading target value of Red.
Continuous display of 0 (minimum) or 2048 (maximum) is considered
a failure of the White Plate data.
Use case
When the scanned image failure occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 2048
Appropriate target value 512 - 2047
8-8
T-8-6
8-8