Canon imageRUNNER C1335 Series Service Manual page 475

Table of Contents

Advertisement

COPIER> ADJUST> CCD
LED-CLB2
Adj sec lgt src LEDSTOP VL(B):clr,300dpi
Details
To adjust the lighting time of the blue color LED which is a secondary
light source of the Scanner Unit in color mode with 300 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
When replacing the Scanner Unit, execute COPIER> FUNCTION>
CCD> CL-AGC and write the value of this item in the service label.
Display/adj/set range
0 to 2048
Default value
496 (25ppm machine)/454 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
The secondary light source exposes light to the light guide at the right
side of CIS (at trailing edge side of original at copyboard reading).
LED2CL-R
Adj LEDSTOP VL (R): color mode, 600 dpi
Details
To adjust the lighting time of the red color LED which is a primary light
source of the Scanner Unit in color mode with 600 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2048
Default value
1192 (25ppm machine)/678 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
LED2CL-G
Adj LEDSTOP VL (G): color mode, 600 dpi
Details
To adjust the lighting time of the green color LED which is a primary light
source of the Scanner Unit in color mode with 600 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2048
Default value
1469 (25ppm machine)/1020 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
8
Service Mode > COPIER > ADJUST > CCD
8
Service Mode > COPIER > ADJUST > CCD
COPIER> ADJUST> CCD
LED2CL-B
Adj LEDSTOP VL (B): color mode, 600 dpi
Details
To adjust the lighting time of the blue color LED which is a primary light
source of the Scanner Unit in color mode with 600 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 2048
Default value
1016 (25ppm machine)/714 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
LED2CLR2
Adj sec lgt src LEDSTOP VL(R):clr,600dpi
Details
To adjust the lighting time of the red color LED which is a secondary light
source of the Scanner Unit in color mode with 600 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
When replacing the Scanner Unit, execute COPIER> FUNCTION>
CCD> CL-AGC and write the value of this item in the service label.
Display/adj/set range
0 to 2048
Default value
1192 (25ppm machine)/678 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
The secondary light source exposes light to the light guide at the right
side of CIS (at trailing edge side of original at copyboard reading).
LED2CLG2
Adj sec lgt src LEDSTOP VL(G):clr,600dpi
Details
To adjust the lighting time of the green color LED which is a secondary
light source of the Scanner Unit in color mode with 600 dpi.
Use case
When replacing the Main Controller PCB/clearing the Reader-related
RAM data
Adj/set/operate method 1) Enter the setting value and press Start key.
2) Turn OFF/ON the main power switch.
Caution
When replacing the Scanner Unit, execute COPIER> FUNCTION>
CCD> CL-AGC and write the value of this item in the service label.
Display/adj/set range
0 to 2048
Default value
1469 (25ppm machine)/1020 (35ppm machine)
Related service mode
COPIER> FUNCTION> CCD> CL-AGC
Supplement/memo
It is updated automatically when the value of CL-AGC is changed.
The secondary light source exposes light to the light guide at the right
side of CIS (at trailing edge side of original at copyboard reading).
8-36
8-36

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Imagerunner c1325 series

Table of Contents