COPIER> DISPLAY> DENS
CHG-DC-K
Dspl Pry charge DC voltg (Bk)& gain VL
Details
To display the latest output value of primary charging DC voltage (Bk).
Use case
When low density or fogging occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1500 to 0
Unit
1 V
Appropriate target value -1400 - -1200
D-K-TRGT
Dspl of ATR ctrl Bk patch target density
Details
To display the Bk patch image target density created by ATR control.
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 65535
Appropriate target value 450 - 640
P-D-P-Y
Dspl Y/M (R) drk crrnt (Pwave):ATR ctrl
Details
To display the Y/M color dark current (P-wave) detected by the
Registration Patch Sensor Unit (Rear) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 50 - 150
P-D-P-C
Dspl C/Bk (F) drk crrnt (Pwave):ATR ctrl
Details
To display the C/Bk color dark current (P-wave) detected by the
Registration Patch Sensor Unit (Front) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 50 - 150
P-B-P-Y
ITB rear base intensity (Pwave):ATR ctrl
Details
To display the ITB background light intensity (P-wave) detected by the
Registration Patch Sensor Unit (Rear) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 300 - 650
8
Service Mode > COPIER > DISPLAY > DENS
8
Service Mode > COPIER > DISPLAY > DENS
COPIER> DISPLAY> DENS
P-B-P-C
ITB frt base intensity (Pwave):ATR ctrl
Details
To display the ITB background light intensity (P-wave) detected by the
Registration Patch Sensor Unit (Front) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 300 - 650
P-B-S-Y
ITB rear base intensity (Swave):ATR ctrl
Details
To display the ITB background light intensity (S-wave) detected by the
Registration Patch Sensor Unit (Rear) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 0 - 239
P-B-S-C
ITB frt base intensity (Swave):ATR ctrl
Details
To display the ITB background light intensity (S-wave) detected by the
Registration Patch Sensor Unit (Front) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
P-D-S-Y
Dspl of ATR ctrl Y dark current (S-wave)
Details
To display the Y/M color dark current (S-wave) detected by the Patch
Sensor (Rear) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 100 - 200
P-D-S-C
Dspl of ATR ctrl C dark current (S-wave)
Details
To display the C/Bk color dark current (S-wave) detected by the Patch
Sensor (Front) at ATR control.
At low density or fogging deterioration, use this mode to check
whether there is a problem in the Patch Sensor.
Use case
At low density or fogging deterioration
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 1023
Appropriate target value 100 - 200
8-12
8-12