4
Disassembly/Assembly > Image Formation System > Removing the Toner Bottle Mount (Y/M/C/Bk) > Procedure
2) Disconnect the connector [1], and remove the Harness Guide [A] and the screw [2].
1x
[1]
[A]
1x
3) Remove the Toner Bottle Mount (Bk) [2] while pressing down the shutter [1].
• 6 Bosses [3]
[1]
[3]
[3]
[3]
4
Disassembly/Assembly > Image Formation System > Removing the Toner Bottle Mount (Y/M/C/Bk) > Procedure
1x
[A]
[2]
F-4-342
[2]
F-4-343
NOTE: Actions after assembly
Execute Auto Adjust Gradation and Correct Print Color Mismatch.
Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Auto Adjust
Gradation > Full Adjust
Settings/Registration > Adjustment/Maintenance > Adjust Image Quality > Correct Print
Color Mismatch
4-136