Canon imageRUNNER C1335 Series Service Manual page 506

Table of Contents

Advertisement

COPIER> ADJUST> FEED-ADJ
ADJ-ENV
Cst1 write start pstn in horz scan:envlp
Details
To adjust the image write start position in the horizontal scanning
direction when feeding envelope from the Cassette 1.
To specify the position of envelope relative to the position specified by
ADJ-C1.
As the value is changed by 1, the left margin is changed by 0.1 mm.
+: Left margin becomes larger. (An image moves to the right.)
-: Left margin becomes smaller. (An image moves to the left.)
Use case
Upon user's request
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and press
Start key.
Caution
In principle, the image write start position of envelope needs to be set
with printer driver by the user. If the user points out that it is bothersome
to make a setting whenever making an output, set this item.
Display/adj/set range
-23 to 15
Unit
0.1 mm
Appropriate target value -8
Default value
-8
Related service mode
COPIER> ADJUST> FEED-ADJ> ADJ-C1
8
Service Mode > COPIER > ADJUST > CST-ADJ
T-8-21
8
Service Mode > COPIER > ADJUST > CST-ADJ
■ CST-ADJ
COPIER> ADJUST> CST-ADJ
CST-VLM1
Adj Cassette 1 level detect threshold VL
Details
To adjust the timing to switch the scale indicating paper level in the
Cassette 1 from "3" to "2".
As the value is larger, switching of the level display becomes earlier.
For example, if you prefer to switch the scale when paper level reaches
25 mm instead of 15 mm, place a stack of papers which height is
approx. 25 mm in the cassette and then increase the setting value by 1
at a time until the scale becomes "2".
If the scale is switched although paper level is 40 mm, place a stack
of papers which height is approx. 35 mm in the cassette and then
decrease the setting value by 1 at a time until the scale becomes "3".
If the value that satisfy both of the above conditions is set, the scale is
switched when paper level is in the range of 25 to 35 mm.
Use case
Upon user's request (to individually adjust the timing to switch the
paper level display)
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press Start key.
2) Pull out and then insert the cassette.
Caution
• The setting is reflected after removing and then installing the
cassette.
• When the value is increased/decreased greatly, the actual timing
may be deviated from the target. Therefore, change the value by 1 at
a time while checking the scale.
Display/adj/set range
-4 to 4
Appropriate target value 0
Default value
0
Supplement/memo
The timing to switch the scale of paper level from "3" to "2" varies (9
to 40 mm) due to individual difference of the motor. With this item, the
variation is corrected.
Since paper levels corresponding to the other scales can be detected
almost correctly, there is no need to adjust the timing of switching.