Error
Detail
Item
code
Code
E806 0201 Title
Drive Unit Cooling Fan error
Description The Drive Unit Cooling Fan rotated for more than the specified period of
time after the stop of drive.
Remedy
[Related parts]
• Harness between the DC Controller PCB (UN04/J191) and the Drive
Unit Cooling Fan (FM02)
• Drive Unit Cooling Fan (FM02)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
E806 0300 Title
Delivery Cooling Fan error
Description The Delivery Cooling Fan did not rotate for the specified period of time
since the start of drive.
Remedy
[Related parts]
• Harnesses from the DC Controller PCB to the Delivery Cooling Fan
1. DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of
replacement: CABLE, MAIN)
2. Relay Connector (3P) to Delivery Cooling Fan (FM03)
• Delivery Cooling Fan (FM03)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
7
Error•Jam•Alarm > Error Code > Error Code Details
Description
7
Error•Jam•Alarm > Error Code > Error Code Details
Error
Detail
Item
code
Code
E806 0301 Title
Delivery Cooling Fan error
Description The Delivery Cooling Fan rotated for more than the specified period of
time after the stop of drive.
Remedy
[Related parts]
• Harnesses from the DC Controller PCB to the Delivery Cooling Fan
1. DC Controller PCB (UN04/J151) to Relay Connector (3P) (Unit of
replacement: CABLE, MAIN)
2. Relay Connector (3P) to Delivery Cooling Fan (FM03)
• Delivery Cooling Fan (FM03)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.
E806 0400 Title
Duplex Cooling Fan error
Description The Duplex Cooling Fan in the Right Cover did not rotate for the specified
period of time since the start of drive.
Remedy
[Related parts]
• Harnesses from the DC Controller PCB to the Duplex Cooling Fan
1. DC Controller PCB (UN04/J122) to Relay Connector (17P) (Unit of
replacement: 2ST TRANS. H.V. CONTACT ASS'Y)
2. Relay Connector (17P) to Relay Connector (3P) (Unit of
replacement: CABLE, DOOR, RIGHT)
3. Relay Connector (3P) to Relay Connector (3P) (Unit of
replacement: CABLE, DOOR FAN, RIGHT)
4. Relay Connector (3P) to Duplex Cooling Fan (FM04)
• Duplex Cooling Fan (FM04)
• DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER
PCB ASSEMBLY)
[Points to note at work] When checking the harness/cable or connector,
perform the following work.
1. Disconnect and then connect the connector to check that there is no
bent pin and cable disconnection.
2. Visually check that the harness is not caught or open circuit.
3. If there is any error, replace the corresponding harness/cable.
[Remedy] Check/replace the related parts.