Canon imageRUNNER C1335 Series Service Manual page 450

Table of Contents

Advertisement

COPIER> DISPLAY> DENS
REF-Y
Dspl of Y developer density target value
Details
To display the developer density target value for the ATR Sensor (Y).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-M
Dspl of M developer density target value
Details
To display the developer density target value for the ATR Sensor (M).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-C
Dspl of C developer density target value
Details
To display the developer density target value for the ATR Sensor (C).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
REF-K
Dspl Bk developer density target value
Details
To display the developer density target value for the ATR Sensor (Bk).
Use case
When analyzing the cause of a problem
Adj/set/operate method N/A (Display only)
Display/adj/set range
0 to 255
Appropriate target value 50 - 200
DEV-DC-Y
Dspl of developing DC voltage (Y)
Details
To display the latest Y developing DC voltage Vdc.
Use case
• When image failure occurs due to carrier adherence
• When fogging appears
• When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
DEV-DC-M
Dspl of developing DC voltage (M)
Details
To display the latest M developing DC voltage Vdc.
Use case
• When image failure occurs due to carrier adherence
• When fogging appears
• When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
8
Service Mode > COPIER > DISPLAY > DENS
8
Service Mode > COPIER > DISPLAY > DENS
COPIER> DISPLAY> DENS
DEV-DC-C
Dspl of developing DC voltage (C)
Details
To display the latest C developing DC voltage Vdc.
Use case
• When image failure occurs due to carrier adherence
• When fogging appears
• When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
DEV-DC-K
Dspl of developing DC voltage (Bk)
Details
To display the latest Bk developing DC voltage Vdc.
Use case
• When image failure occurs due to carrier adherence
• When fogging appears
• When fogging is deteriorated
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1000 to 0
Unit
1 V
Appropriate target value -570 - -450
CHG-DC-Y
Dspl of primary charging DC voltage (Y)
Details
To display the latest primary charging DC voltage of Y-color.
Use case
When low density or fogging occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1500 to 0
Unit
1 V
Appropriate target value -1400 - -1200
CHG-DC-M
Dspl of primary charging DC voltage (M)
Details
To display the latest primary charging DC voltage of M-color.
Use case
When low density or fogging occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1500 to 0
Unit
1 V
Appropriate target value -1400 - -1200
CHG-DC-C
Dspl of primary charging DC voltage (C)
Details
To display the latest primary charging DC voltage of C-color.
Use case
When low density or fogging occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1500 to 0
Unit
1 V
Appropriate target value -1400 - -1200