COPIER> COUNTER> DRBL2SET
C4-FD-RL
Cassette4 Feed Roller parts counter
Details
Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To change the estimated life: Select the item, enter the value, and
then press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C2-PU-RL
Cassette 2 Pickup Roller parts counter
Details
Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To change the estimated life: Select the item, enter the value, and
then press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
C2-SP-RL
Cassette2 Separation Roller prts counter
Details
Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To change the estimated life: Select the item, enter the value, and
then press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
1 sheet
Default value
0
C2-FD-RL
Cassette2 Feeding Roller prts counter
Details
Estimated life
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To change the estimated life: Select the item, enter the value, and
then press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Unit
1 sheet
Default value
0
8
Service Mode > COPIER > COUNTER > DRBL-1
T-8-57
8
Service Mode > COPIER > COUNTER > DRBL-1
■ DRBL-1
COPIER> COUNTER> DRBL-1
LSR-DRV
Laser Scanner Unit parts counter
Details
Total counter value from the previous replacement
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then enter "0" and
press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
TR-BLT
ITB parts counter
Details
Total counter value from the previous replacement
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then enter "0" and
press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
2TR-ROLL
Sec Transfer Outer Roller parts counter
Details
Total counter value from the previous replacement
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then enter "0" and
press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
Supplement/memo
This is commonly used as operator maintenance parts counter.
PT-DRM
Drum Unit (Bk) parts counter
Details
Total counter value from the previous replacement
Use case
When checking the consumption level of parts
Caution
When replacing the drum unit, clear the counter value automatically.
Display/adj/set range
0 to 99999999
Default value
0
C1-PU-RL
Cassette 1 Pickup Roller parts counter
Details
Total counter value from the previous replacement
Use case
When checking the consumption level of parts/replacing the parts
Adj/set/operate method To clear the counter value: Select the item, and then enter "0" and
press Start key.
Caution
Clear the counter value after replacement.
Display/adj/set range
0 to 99999999
Default value
0
8-117
8-117