Storage - Alcatel 1850 TSS-320 Technical Handbook

Metro core transport service switch
Hide thumbs Also See for 1850 TSS-320:
Table of Contents

Advertisement

5.7.5 Storage

The 1850 TSS-320 equipment meet the following requirements Vs. Storage:
ETS 300 019-1-1: 1992, class 1.2
Class 1.2: weatherprotected, not temper. controlled storage location.
This class applies to weather protected storage having neither temperature nor humidity control. The
location may have openings directly to the open air, i.e., it may be only partly weatherproofed. The
climatogram is shown on Figure 115.on page 198.
This class applies to storage locations:
where equipment may be exposed to solar radiation and temporarily to heat radiation: They may also
be exposed to movements of the surrounding air due to draughts, e.g. through doors, windows or
other openings. They may be subjected to condensed water, dripping water and to icing. They may
also be subjected to limited wind-driven precipitation including snow;
where mould growth or attacks by animals, except termites, may occur;
with normal levels of contaminants experienced in urban areas with industrial activities scattered
over the whole area, ad/or with heavy traffic;
in areas with sources of sand or dust, including urban areas;
with vibration of low significance and insignificant shock.
The conditions of this class may occur in:
unattended buildings;
some entrances of buildings;
some garages and shacks.