7.5.45.6
Fig. 7-140
L

Start via touch probe initiator (terminal X5/E5)

Stop!
In the default setting the terminal X5/E5 is assigned to another function.
Function
Set C0757 = 1.
The function is activated by simultaneously setting the inputs:
– DFRFG-QSP and DFRFG-RESET = HIGH.
Starting procedure:
– Signals at DFRFG-QSP and DFRFG-RESET = LOW.
– Otherwise touch probe signals are ignored.
A LOW-HIGH edge at terminal X5/E5 starts the process:
DFRFG-OUT
DFRFG-IN
Touch-Probe X5/E5
DFRFG-QSP
DFRFG-RESET

Start via touch probe initiator (terminal X5/E5)