Installation
Supply via external voltage source
X5
28 E1 E2 E3 E4 E5
Fig. 4-17
Connection of the digital input signals for external voltage supply
Tip!
The supply of the digital input signals via an external voltage source allows a backup operation in
the event of mains failure. After switching off the mains voltage all actual values are still detected
and processed.
Connect the positive pole of the external voltage source with X5/59 to create the backup
operation in the event of mains failure.
The external voltage must be able to supply a current
The starting current of the external voltage source is not limited by the controller. Thus, Lenze
recommends using voltage sources with current limitation or with an internal impedance of
Z > 1
4-26
GND2
39
A1 A2 A3 A4 ST ST 59
+
24 V ext.
(+18 VDC -0% ... +30 VDC +0%)
Minimum wiring required for operation
.
EDSVS9332P-B EN 3.0
+24V
1 A .