Motor Temperature Monitoring Oh8 - Lenze 9300 System Manual

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
7.6.3.15
Fig. 7-248
Name
T1/T2
MONIT-OH8
L

Motor temperature monitoring OH8

Purpose
Motor protection

Motor temperature monitoring OH8

Signal
Type
DIS
DIS format
-
-
-
d
-
-
Function
The signal OH8 is derived from the digital signal via the terminals T1, T2 next to the power terminals
UVW. The threshold and the hysteresis depend on the encoder system (DIN 44081) (see Chapter
4.2.10).
Stop!
When using this input as a motor protection: If the monitoring is set to WARNING or OFF, the motor
can be destroyed in case of further overload.
Features:
LECOM no.: 58, 2058
Reaction: TRIP, WARNING or OFF
MONIT
DIN44081
T1/T2
MONIT-OH8
Source
CFG
List
Lenze
-
-
-
-
-
-
-
-
EDSVS9332P-D21 EN 3.0
Configuration
Note
7-309