Commissioning
5.10.3

Manual homing

The controller can perform all positioning tasks only with a defined reference point (zero point).
Click on the "Control" button in the "Basic settings" dialog box.
Fig. 5-20
Dialog box " Control"
Field
1
5
4
2
3
5-26
Command
Select "Manual operation"
Controller "Start"
Select "Manual homing".
Reset "Manual homing".
Override the reference switch.
EDSVS9332P-C EN 3.0
Function
Manual operation active
With drive status "OK", "Start" is possible.
Starts the controller if there is no interference.
The drive uses the reference parameters for positioning.
The drive stops.
The drive traverses to the next zero position of the rotor and brakes to a standstill.
This position is now considered to be the reference point for all positioning data.
Status display "Reference OK" is displayed after successful reference homing.
Terminal X5/A4 = HIGH
9300pos044