Analog Input Via Terminal 1,2/3,4 (Ain) - Lenze 9300 System Manual

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
7.5.21
Fig. 7-53
Fig. 7-54
L

Analog input via terminal 1,2/3,4 (AIN)

Purpose
This FB is the interface for analog signals as
setpoint input,
actual value input and
parameter control.
Analog input via terminal 1,2 (AIN1)
Signal
Name
Type
AIN1-OFFSET
a
C0404/1
AIN1-GAIN
a
C0404/2
AIN1-OUT
a
Special feature of the input terminals 1,2
A dead travel element can be integrated into the output signal at AIN1 via code C0034.
Together with the jumper position X2 (controller front) the function 4 ... 20 mA can be
implemented as current guide value.
The signal is read cyclically (1 ms).
Analog input via terminal 3, 4 (AIN2)
Special feature of AIN2
The signal is read cyclically every 250 µs.
Signal
Name
Type
AIN2-OFFSET
a
C0409/1
AIN2-GAIN
a
C0409/2
AIN2-OUT
a
1
+
2
+
AIN1-OFFSET
C0402
C0404/1
AIN1-GAIN
C0403
C0404/2
DIS
DIS format
CFG
dec [%]
C0402
dec [%]
C0403
-
-
-
3
4
AIN2-OFFSET
C0407
C0409/1
AIN2-GAIN
C0408
C0409/2
DIS
DIS format
CFG
dec [%]
C0407
dec [%]
C0408
-
-
-
EDSVS9332P-D21 EN 3.0
Function library
C0034
AIN1
AIN1-OUT
C0400
Source
List
Lenze
1
19502
-
1
19504
-
-
-
-
AIN2
AIN2-OUT
+
+
C0405
Source
List
Lenze
1
19503
-
1
19505
-
-
-
-
Note
Note
7-101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents