Cancel stand-by operation
The stand-by operation can be aborted via two ways:
1. Abortion via FB input "POS-STDBY-STP"
2. Abortion via touch-probe signal at terminal X5/E1 ... X5/E4
Abortion via FB input "POS-STDBY-STP"
E.g.: Linkage with a digital control signal via a fieldbus or a function block interconnection.
The stand-by operation is aborted and the drive will be reset to positioning when POS-STDBY-STP
= HIGH. Positioning accelerates /decelerates the drive with the profile parameters of the PS to the
preset final speed of the PS. Further PS functions will only be processed when the final speed has
been reached.
Abortion via touch-probe signal at terminal X5/E1 ... X5/E4
E. g.: For accurate positioning over a mark signal after operation with a master frequency.
A TP input has been enabled during stand-by operation. When the TP signal occurs, the stand-by
operation is aborted and the drive is reset to positioning. A positioning action follows comprising the
TP residual distance and starting from the TP position. The positioning traverses the drive using the
profile parameters of the PS. Only after positioning has been completed, the following PS functions
will be processed.
7-82
Prg-Start
N-IN
STDBY-ACT
STDBY-STP
Prg-Start
N-IN
STDBY-ACT
TP
EDSVS9332P-D21 EN 3.0
PS1
PS2
PS1
PS2
0
9300POS036