Lenze 9300 System Manual page 471

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Code
No.
LCD
C0517
1 USER MENU
2 USER MENU
3 USER MENU
4 USER MENU
5 USER MENU
6 USER MENU
7 USER MENU
8 USER MENU
9 USER MENU
10 USER MENU
11 USER MENU
12 USER MENU
13 USER MENU
14 USER MENU
15 USER MENU
16 USER MENU
17 USER MENU
18 USER MENU
... ...
31 USER MENU
32 USER MENU
[C0520] IN
[C0521] VP-DIV
[C0522] RAT-DIV
[C0523] A-TRIM
[C0524] N-TRIM
[C0525] 0-PULSE
[C0526] RESET
[C0527] SET
C0528
1 0-PULSE A
2 OFFSET
C0529 MULTIP OFFSET
C0530 DF EVALUATION
C0531 ACT 0 DIV
C0532 0-PULSE/TP
C0533 VP DENOM
7-340
Possible settings
Lenze
Selection
0.00
51.00
C0051/0 MCTRL-NACT
54.00
C0054/0 Imot
56.00
C0056/0 MCTRL-MSET2
46.00
C0046/0 N
49.00
C0049/0 NADD
183.00 C0183/0 Diagnostics
168.01 C0168/1 Fail no. act
86.00
C0086/0 Mot type
22.00
C0022/0 Imax current
5.00
C005/0 signal cfg
11.00
C0011/0 Nmax
12.00
C0012/0 Tir
13.00
C0013/0 Tif
105.00 C0105/0 QSP Tif
39.01
C0039/1 JOG setpoint
70.00
C0070/0 Vp speed CTRL
71.00
C0071/0 Tn speed CTRL
0
not assigned
0
not assigned
94.00
C0094/0 Password
3.00
C0003/0 Par save
1000
FIXEDPHI-0
1000
FIXED0%
1000
FIXED0%
1000
FIXED0%
1000
FIXED0%
1000
FIXED0
1000
FIXED0
1000
FIXED0
.
9
-2
10
1
-20000
0
0
with g factor
1
without g factor
1
1
1
1
Index pulse
2
Touch probe
3
Index pulse and touch probe
1
1
EDSVS9332P-D22 EN 3.0
1999.00 User menu
{0.01}
→ Selection list 4 DFSET
→ Selection list 1 DFSET
→ Selection list 1 DFSET
→ Selection list 1 DFSET
→ Selection list 1 DFSET
→ Selection list 2 DFSET
→ Selection list 2 DFSET
→ Selection list 2 DFSET
.
9
{1}
2
10
{1}
20000 DFSET
{1}
16384 DFSET
{1}
32767 DFSET
Important
Up to 32 entries
U d th
Under the subcodes the numbers of the
b d
th
b
desired codes are entered
desired codes are entered.
The input is done in the format xxx.yy
The input is done in the format xxx.yy
– xxx: Code number
xxx: Code number
– yy: Subcode number
yy
It is not checked whether the entered code
exists
exists.
Input signal configuration
Configuration - gain factor of numerator
Configuration - gearbox factor of numerator
Configuration - phase trimming
Speed trimming of DFSET
Configuration - one-time zero pulse activation
Configuration - integrator resetting
Configuration - integrator setting
DFSET
Phase difference between two zero pulses
Offset from C0523 × C0529 + C0252
Offset multiplier
DFSET
Master frequency evaluation
Evaluation of the setpoint integrator
(with/without gearbox factor)
Actual zero pulse divider
DFSET
Selection of index pulse and/or touch probe of
the feedback system
Gain factor denominator
L
f th

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents