Motor Temperature Monitoring - Lenze 9300 System Manual

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
4.2.10
Selection of the sensor
type
Other monitoring
Alternative monitoring
Reactions
Connection
Fault message
Possible reactions
Tripping
temperature
Notes
L

Motor temperature monitoring

Continuous temperature sensor KTY
– "Linear" temperature sensor in the motor winding (standard for Lenze motors MDXKX, MDXQA and MDXMA)
PTC thermistor
– PTC thermistor with defined tripping temperature (acc. to DIN 44081 and DIN 44082)
Thermal contact TKO
– Thermostat/normally-closed contact
KTY, PTC and TKO do not offer complete protection. To improve the monitoring, Lenze recommends the use of a bimetal relay.
Comparators (CMP1 ... CMP3) monitor and a time element (TRANS1 ... TRANS4) limits the motor current for small speeds or motor
standstill.
This function can be implemented by interconnecting the corresponding function blocks.
different, depending on the temperature monitoring.
Stop!
Do not connect an external voltage to the inputs.
Lenze motors
MDXKX, MDXQA and MDXMA
Resolver input X7:
– Pin X7/8 = +,
Pin X7/9 = -
Encoder input X8:
– Pin X8/8 = +,
Pin X8/5 = -
(MONIT-)OH3
(MONIT-)OH7
The corresponding monitoring and thus the following codes are preset under C0086
Trip
Warning (C0584
(C0583 = 0)
= 2)
OFF
OFF
(C0583 = 3)
(C0584 = 3)
fixed at 150 ° C
adjustable
45°C ... 150°C
(C0121)
Monitoring is active in the default
setting.
If resolver (X7) and encoder (X8) are
operated together:
– Connect KTY only at one connector
(X7 or X8)
– Do not connect KTY connection of
the other female connector
For further information on the
connection of the thermal sensor,
please consult the description of the
feedback system
7-291
with thermostat
with sensor for continuous
temperature detection
Terminals T1/T2 next to the
Resolver input X7:
terminals U, V, W
– Pin X7/8 = +,
Pin X7/9 = -
Encoder input X8:
– Pin X8/8 = +,
Pin X8/5 = -
(MONIT-)OH8
(MONIT-)OH3
Trip (C0585 = 0)
Trip
(C0583 = 0)
Warning
(C0585 = 2)
OFF
(C0583 = 3)
OFF (C0585 = 3)
fixed, (depending on the
fixed at 150 °C
PTC/thermostat):
PTC: at R ϑ > 1600 Ω
Deactivate monitoring
Input characteristic. (
via X7 or X8 under
Deactivate monitoring via X7 or X8
C0583=3 and C0584=3
under C0583=3 and C0584=3
Connection to DIN
44081
(see also Fig. 4-23).
EDSVS9332P-B EN 3.0
Installation
Motors of other manufacturers
with thermal contact or
PTC acc. to DIN
44081/44082
Terminals T1/T2 next to the
terminals U, V, W
(MONIT-)OH7
(MONIT-)OH8
Warning (C0584
Trip (C0585 = 0)
= 2)
Warning
OFF
(C0585 = 2)
(C0584 = 3)
OFF (C0585 = 3)
adjustable
fixed, (depending on the
45°C ... 150°C
PTC/thermostat):
PTC: at R ϑ > 1600Ω
(C0121)
4-36)
Deactivate monitoring
via X7 or X8 under
C0583=3 and C0584=3
Connection to DIN
44081
(see also Fig. 4-23).
We recommend a Ziehl
PTC (up to 150 °C)
K15301075 or a
thermostat.
4-35