Analog output via terminal 62/63 (AOUT)

Purpose
AOUT1 and AOUT2 can be used as monitor outputs.
Internal analog signals can be output as voltage signals and be used e.g. as display values or
setpoints for slaves.
Analog output via terminal X6/62 (AOUT1)
Signal
Name
Type
AOUT1-IN
a
C0434/1
AOUT1-GAIN
a
C0434/3
AOUT1-OFFSET
a
C0434/2
Analog output via terminal X6/63 (AOUT2)
Signal
Name
Type
AOUT2-IN
a
C0439/1
AOUT2-GAIN
a
C0439/3
AOUT2-OFFSET
a
C0439/2
Function
The value at input AOUTx-IN is multiplied with the value at input AOUTx-GAIN.
– The formula for the multiplication is: 100% * 100% = 100% .
The result of the multiplication is limited to ±200% .
The limited value is added to the value which is applied at input AOUTx-OFFSET.
– The formula for the addition is 50% + 10% = 60% . The result of the calculation is mapped
in such a way that 100% = 10 V.
The result of the addition is limited again to ±200% .
The result of the calculation is mapped in such a way that 100% = 10 V and is output as a
signal at terminal 62 or 63.
C434/1
AOUT1-IN
C0431
AOUT1-GAIN
C0433
C0434/3
AOUT1-OFFSET
C0432
C0434/2
DIS
DIS format
CFG
dec [%]
C0431
dec [%]
C0433
dec [%]
C0432
C439/1
AOUT2-IN
C0436
AOUT2-GAIN
C0438
C0439/3
AOUT2-OFFSET
C0437
C0439/2
DIS
DIS format
CFG
dec [%]
C0436
dec [%]
C0438
dec [%]
C0437
EDSVS9332P-D21 EN 3.0
Function library
AOUT1
+
62
+
Source
List
Lenze
1
5001
-
1
19510
-
1
19512
-
AOUT2
+
63
+
Source
List
Lenze
1
5002
-
1
19511
-
1
19513
-
Note
Note
7-107