Lenze 9300 System Manual page 423

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
Configuration
Display
Meaning
Sd5
Encoder fault at X6/1 X6/2 (C0034 = 1)
Sd6
Sensor fault: motor temperature (X7 or X8)
Sd7
Error of the absolute value encoder at X8
Sd8
Error of the SinCos encoder
Factory setting
7-294
TRIP
possible
-
not possible
EDSVS9332P-D21 EN 3.0
Message
Warning
FAIL-QSP
-
-
-
-
-
-
-
-
-
-
*
possible, but the drive can be destroyed if the fault is
not removed immediately.
off
Code
Notes
C0598
C0594
Part E,
Part E,
8 5
8-5
C0025
C0580
Part E,
8-5
L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents