Sample And Hold Function (S&H) - Lenze 9300 System Manual

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
7.5.74
Fig. 7-208
L
Sample and hold function (S&H)
Purpose
The FB can save analog signals. The saved value is also available after mains switching.
Sample and hold function (S&H1)
Signal
Name
Type
S&H1-IN
a
C0572
S&H1-LOAD
d
C0573
S&H1-OUT
a
Function
With S&H1-LOAD = HIGH the signal at the input S&H1-IN is switched to the output
S&H1-OUT.
With S&H1-LOAD = LOW the output S&H1-OUT is disconnected from the input S&H1-IN and
outputs the value which was last valid.
Saving in the case of mains disconnection:
Keep S&H1-LOAD to LOW level when disconnecting the supply voltage (mains, DC bus or
terminal 59).
Keep S&H1-LOAD to LOW level when connecting the supply voltage (mains, DC bus or
terminal 59).
S&H1-IN
S&H
C0570
C0572
S&H1-LOAD
C0571
C0573
DIS
DIS format
CFG
dec [%]
C0570
bin
C0571
-
-
-
EDSVS9332P-D21 EN 3.0
Function library
S&H1
S&H1-OUT
Source
List
Lenze
1
1000
2
1000
LOW = save
-
-
Note
7-257

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents