Function library
7.5.28.2

Signal processing

Reading the BCDs:
Output
BCDx-EOT
BCDx-NEW-DATA
BCDx-DATA-FLT
BCDx-FAIL
Fig. 7-82
Signal shape for FB BCD1 for the transmission to the target code
Transmission sequence of data to the target code:
Output
BCDx-LOAD
BCDx-BUSY
BCDx-FAIL
For the data conditioning for the target code see FB FEVAN.
7-120
Signal
Function
LOW
Beginning of the BCD reading.
HIGH
If
all 8 absolute value digits and the sign are transmitted or
"CANCEL" has been identified.
LOW
After a LOW-HIGH edge at BCD-READ.
HIGH
After the transmission of a BCD is completed.
HIGH
If "BCD error" has been identified (see table in chapter 7.5.28.1).
HIGH
If
the permissible value range for the target code is exceeded or
BCDx-DATA-FLT = HIGH has occurred before.
C o r r e c t t r a n s m i s s i o n
Signal
Function
LOW-HIGH edge
Transmits the signal to the target code.
HIGH
For the time of transmission
HIGH
If a transmission error occurs.
Only another LOW-HIGH edge at BCDx-LOAD switches BCDx-FAIL = LOW.
Transmission error:
No target code
No target subcode.
transmitted data are out of the target code limits.
"BCD error" has been identified (BCDx-DATA-FLT = HIGH).
The target code is inhibited. Code can only be written when the controller is inhibited.
EDSVS9332P-D21 EN 3.0
W r o n g t r a n s m i s s i o n
B C D 1 x - F A I L
B C D 1 x - B U S Y
B C D 1 x - L O A D
(
7-204)