Fig. 7-86
7.5.29.1
L
Holding brake (BRK)
Signal
Name
Type
BRK-SET
d
C0459
BRK-NX
a
C0458/1
BRK-SIGN
a
C0458/2
BRK-M-SET
a
BRK-T-ACT
a
BRK-T-RELEASE
a
Function
The signals N-ACT, M-ACT, N-SET and BRK-Nx are processed as absolute values within the function
block.

Applying the brake

Purpose
A HIGH-Signal at the BRK-SET input
activates the function. The BRK-QSP
output is simultaneously set to HIGH.
This signal can be used to decelerate
the drive to zero speed via a
deceleration ramp.
Function
If the setpoint speed falls below the
value set at the BRK-Nx input, the
BRK-OUT output is set to HIGH. In order
to ensure a fail-safe design this signal
must be inverted at the output (e.g. via
C0118).
DIS
DIS format
CFG
bin
C0451
dec [%]
C0450
dec [%]
C0452
-
dec [%]
C0244
-
dec
C0195
-
dec
C0196
BRK-SET
BRK-QSP
MCTRL-NSET2
BRK-OUT
BRK-RSP
EDSVS9332P-D21 EN 3.0
Function library
BRK
Source
List
Lenze
2
1000
-
1
1000
Speed threshold from which the drive may
output the signal "Close brake". The signal
source for this input can be a control code,
a fixed value, or any other analog FB
output.
1
1000
Direction of the torque with which the drive
is to set up a torque against the brake. The
signal source for this input can be a control
code, a fixed value, or any other FB output.
-
0.00
Holding torque of the DC injection brake
100 % = value of C0057
-
99.9
Brake engaging time
-
0.0
Brake application time
C0195
Note
t
t
|BRK-Nx|
|BRK Nx|
t
t
t
7-127