Fig. 7-210
L
SELPH2
Function block SELPH2
Signal
Name
Type
SELPH2-SELECT
a
C1668
SELPH2-IN1
ph
C1669/1
SELPH2-IN2
ph
C1669/2
SELPH2-IN3
ph
C1669/3
SELPH2-IN4
ph
C1669/4
SELPH2-IN5
ph
C1669/5
SELPH2-IN6
ph
C1669/6
SELPH2-IN7
ph
C1669/7
SELPH2-IN8
ph
C1669/8
SELPH2-OUT
ph
-
-
C1665
Function
An analog signal at SELPHx-SELECT directly selects an input and switches it to SELPHx-OUT.
– If SELPHx-SELECT = 0, SELPHx-OUT switches to FIXED 0 INC.
– If SELPHx-SELECT < 0, SELPHx-OUT switches to FIXED 0 INC.
– If SELPHx-SELECT > 8, SELPHx-OUT switches to SELPHx-IN8.
Tip!
You can select an input via a digital signal by connecting the FB CONVDAx before SELPHx-SELECT.
0
FIXED0INC
SELPH2-IN1
1
C1667/1
C1669/1
SELPH2-IN2
2
C1667/2
C1669/2
SELPH2-IN3
3
C1667/3
C1669/3
SELPH2-IN4
4
C1667/4
C1669/4
SELPH2-IN5
5
C1667/5
C1669/5
SELPH2-IN6
6
C1667/6
C1669/6
SELPH2-IN7
7
C1667/7
C1669/7
SELPH2-IN8
8
C1667/8
C1669/8
SELPH2-SELECT
C1666
C1668
Source
DIS
DIS format
CFG
dec
C1666
dec [inc]
C1667/1
dec [inc]
C1667/2
dec [inc]
C1667/3
dec [inc]
C1667/4
dec [inc]
C1667/5
dec [inc]
C1667/6
dec [inc]
C1667/7
dec [inc]
C1667/8
-
-
-
dec
-
EDSVS9332P-D21 EN 3.0
Function library
SELPH2
SELPH2-OUT
8
C1665
0
Note
List
1
-
3
-
3
-
3
-
3
-
3
-
3
-
3
-
3
-
-
-
-
displays the current selection
7-259

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents