Lenze 9300 System Manual page 242

Servo position controller
Hide thumbs Also See for 9300:
Table of Contents

Advertisement

Show/Hide Bookmarks
Function library
Fig. 7-78
Changeover switch for analog signals (ASW4)
Name
ASW4-IN2
ASW4-IN1
ASW4-SET
ASW4-OUT
Function
This FB is controlled via a binary input. Depending on the input signal, different signals are sent to
the output:
If a HIGH signal is applied at the binary input, the signal which is applied at the ASWx-IN2
input is sent to the output.
If a LOW signal is applied, the signal which is applied at the ASW-IN2 input is sent to the
output.
7-114
A S W 4 - I N 1
C 1 1 6 5 / 1
A S W 4 - I N 2
C 1 1 6 5 / 2
A S W 4 - S E T
C 1 1 6 6
Signal
Type
DIS
DIS format
a
C1167/1
dec [%]
a
C1167/2
dec [%]
d
C1168
bin
a
-
-
EDSVS9332P-D21 EN 3.0
C 1 1 6 7 / 1
0
A S W 4 - O U T
1
C 1 1 6 7 / 2
C 1 1 6 8
Source
CFG
List
Lenze
C1165/1
1
1000
-
C1165/2
1
1000
-
C1166
2
1000
-
-
-
-
-
Note