Networking Virtualization Configuration

© Copyright Lenovo 2016
The following table describes the Networking Virtualization (NWV) configuration 
options.  
Table 373.
Networking Virtualization Configuration Options
Command Syntax and Usage
nwv mode nsx­gw
Enables the VXLAN Gateway.
The default settings is disabled.
Command mode: Global configuration
no nwv mode
Disables the VXLAN Gateway.
Command mode: Global configuration
[no] nsx­gw enable
Enables or disables the VXLAN Gateway on the switch port.
Command mode: Interface port
nwv nsx­gw
Enters the VXLAN Gateway configuration mode.
Command mode: Global configuration
controller ip <IPv4 address> [data­port|mgt­port]
Configures the NSX controller IP address.
Configuration mode: VXLAN Gateway
controller port <TCP port (1‐65534)>
Configures the NSX controller port.
Configuration mode: VXLAN Gateway
no controller
Removes the NSX controller configuration.
Configuration mode: VXLAN Gateway
tunnel ip <IPv4 address>
Configures the VXLAN Gateway tunnel IP address.
Command mode: VXLAN Gateway
no tunnel
Removes the VXLAN Gateway tunnel configuration.
Command mode: VXLAN Gateway
show nwv nsx­gw
Displays VXLAN Gateway information. For a sample output, see page
Command mode: All
Chapter 4: Configuration Commands