802.1X Information - Lenovo RackSwitch G8332 Command Reference Manual

Iscli - industry standard cli command reference for lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8332:
Table of Contents

Advertisement

802.1X Information

54
G8332 Command Reference for ENOS 8.4
The following command displays 802.1X information:
show dot1x information
Command mode: All  
System capability : Authenticator
System status     : disabled
Protocol version  : 1
Guest VLAN status : disabled
Guest VLAN        : none
                                   Authenticator    Backend   Assigned
Port    Auth Mode    Auth Status     PAE State     Auth State   VLAN
­­­­­  ­­­­­­­­­­­­  ­­­­­­­­­­­­  ­­­­­­­­­­­­­­  ­­­­­­­­­­ ­­­­­­­­
*1     force­auth    unauthorized  initialize      initialize   none
*2     force­auth    unauthorized  initialize      initialize   none
*3     force­auth    unauthorized  initialize      initialize   none
The following table describes the IEEE 802.1X parameters.  
Table 20.
802.1X Parameter Descriptions
Parameter
Description
Port
Displays each port's alias. 
Auth Mode
Displays the Access Control authorization mode for the 
port. The Authorization mode can be one of the following:
Auth Status
Displays the current authorization status of the port, either 
authorized or unauthorized.
Authenticator
Displays the Authenticator Port Access Entity State. The 
PAE State
PAE state can be one of the following:
force­unauth
auto
force­auth
initialize
disconnected
connecting
authenticating
authenticated
aborting
held
forceAuth

Advertisement

Table of Contents
loading

Table of Contents