VXLAN Gateway Information

NSX Gateway Information:
Status:                 Enabled
Gateway IP:             192.168.200.30
BFD Status:             Enabled
Controller Connections:
Idx  Type           Peer               State    Inact. ms  Backoff ms  Latest Method
­­­  ­­­­­­­­­­­­­  ­­­­­­­­­­­­­­­­­  ­­­­­­­  ­­­­­­­­­  ­­­­­­­­­­  ­­­­­­­­­­­­­­­­­­
1    SSL (Active)   10.241.43.60:6640  ACTIVE   30000      8000        transact (comment)
2    SSL (Active)   10.241.43.61:6640  ACTIVE   30000      8000        monitor
3    SSL (Active)   10.241.43.62:6640  ACTIVE   30000      8000        transact (comment)
Physical Port Count: 4
VNI­VLAN Mappings Count: 254
­­­­­­­­­­­­­­­­­­­­­­­­­­­
Name         VNI       VLAN   Status
­­­­­­­­­­­  ­­­­­­­­  ­­­­   ­­­­­­
7/1           5001     1      Up
              5002     2      Up
              5003     3      Up
              5004     4      Up
...
182
G8332 Command Reference for ENOS 8.4
The following command displays VXLAN Gateway information:
show nwv nsx­gw