Port Transceiver Status

166
G8332 Command Reference for ENOS 8.4
The following command displays the status of the transceiver module on each 
port:
show interface transceiver
Command mode: All              
Name       TX   Link TXFlt Volts DegsC TXuW  RXuW  Transceiver   Approve
­­­­­­­­­­ ­­­­ ­­­­ ­­­­­ ­­­­­ ­­­­­ ­­­­­ ­­­­­ ­­­­­­­­­­­­­ ­­­­­­­­
QSFP+   1     < NO Device Installed >
Q10G  2/1  N/A  Down ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­A 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110727 S/N:3547Y350VT17C0HC
Q10G  2/2  N/A  Down ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­B 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110727 S/N:3547Y350VT17C0HC
Q10G  2/3  N/A  LINK ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­C 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110727 S/N:3547Y350VT17C0HC
Q10G  2/4  N/A  LINK ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­D 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110727 S/N:3547Y350VT17C0HC
Q10G  3/1  N/A  LINK ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­A 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110530 S/N:3547Y350VT15J25B
Q10G  3/2  N/A  LINK ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­B 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110530 S/N:3547Y350VT15J25B
Q10G  3/3  N/A  Down ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­C 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110530 S/N:3547Y350VT15J25B
Q10G  3/4  N/A  Down ­N/A­ ­N/A­ ­N/A­ ­N/A­ ­N/A­ PasQDBO­D 3m  Approved
  BLADE NETWORK    Part:BN­QS­SP­CBL­3M  Date:110530 S/N:3547Y350VT15J25B
This command displays information about the transceiver module on each port, as 
follows:
Name identifies the port number and media type
TX enable/disable
RXlos: Receive Loss of Signal indicator
TXFlt: Transmission Fault indicator
Volts: Power usage, in volts
DegsC: Temperature, in degrees centigrade
TXuW: Transmit power, in micro‐watts
RXuW: Receive power, in micro‐watts
Media/Transceiver type (LX, LR, SX, SR)
Laser wavelength, in nanometers
Approval status