Show Recent Syslog Messages - Lenovo RackSwitch G8332 Command Reference Manual

Iscli - industry standard cli command reference for lenovo enterprise network operating system 8.4
Hide thumbs Also See for RackSwitch G8332:
Table of Contents

Advertisement

Show Recent Syslog Messages

48
G8332 Command Reference for ENOS 8.4
The following command displays system log messages:
show logging [messages] [severity <0‐7>] [reverse]
Command mode: All  
Current syslog configuration:
  host 0.0.0.0 via MGT port, severity 7, facility 0
  host2 0.0.0.0 via MGT port, severity2 7, facility2 0
  console enabled
  severity level of console output 6
  severity level of write to flash 7
  syslogging all features
  Syslog source loopback interface not set
Nov  2  5:49:53 172.25.254.19 INFO    console: System log cleared by user 
admin.
Nov  2  5:51:23 172.25.254.19 CRIT    system: Fan Mod 4 Removed
Nov  2  5:54:27 172.25.254.19 CRIT    system: **** MAX TEMPERATURE (61) 
ABOVE FAIL THRESH ****
Nov  2  5:54:27 172.25.254.19 CRIT    system: **** PLATFORM THERMAL 
SHUTDOWN ****
Nov  2  6:02:06 0.0.0.0 NOTICE  system: link up on management port MGT
Nov  2  6:02:06 0.0.0.0 INFO    system: booted version 0.0.0 from FLASH 
image2, active configuration
Nov  2  6:02:09 0.0.0.0 NOTICE  system: SR SFP+ inserted at port 63 is 
Approved
Nov  2  6:02:12 0.0.0.0 NOTICE  system: 1m DAC  inserted at port 64 is 
Accepted
Nov  2  6:02:12 0.0.0.0 NOTICE  system: link up on management port MGT
Nov  2  6:03:11 0.0.0.0 NOTICE  ip: MGT port default gateway 172.25.1.1 
operational
Nov  2  6:22:54 172.25.254.19 NOTICE  mgmt: admin(admin) login on Console
Nov  2  6:33:00 172.25.254.19 NOTICE  mgmt: admin(admin) idle timeout 
from Console
Each syslog message has a severity level associated with it, included in text form as 
a prefix to the log message. One of eight different prefixes is used, depending on 
the condition that the administrator is being notified of, as shown here.
EMERG
Indicates the system is unusable
ALERT
Indicates action should be taken immediately
CRIT
Indicates critical conditions
ERR
Indicates error conditions or errored operations
WARNING
Indicates warning conditions
NOTICE
Indicates a normal but significant condition
INFO
Indicates an information message
DEBUG
Indicates a debug‐level message
The severity option filters only syslog messages with a specific severity level 
between 0 and 7, from EMERG to DEBUG correspondingly.
The reverse option displays the output in reverse order, from the newest entry to 
the oldest.

Advertisement

Table of Contents
loading

Table of Contents