ACL Metering Configuration

424
G8332 Command Reference for ENOS 8.4
These commands define the Access Control profile for the selected ACL.  
Table 198.
ACL Metering Configuration Options 
Command Syntax and Usage
access­control list <1‐256> meter action {drop|pass}
Configures the ACL Meter to either drop or pass out‐of‐profile traffic.
Command mode: Global configuration
access­control list <1‐256> meter committed­rate <64‐40000000>
Configures the committed rate, in kilobits per second. The committed rate 
must be a multiple of 64.
Command mode: Global configuration
[no] access­control list <1‐256> meter enable
Enables or disables ACL Metering.
Command mode: Global configuration
access­control list <1‐256> meter maximum­burst­size <32‐4096>
Configures the maximum burst size, in kilobits. Enter one of the following 
values for mbsize: 32, 64, 128, 256, 512, 1024, 2048, 4096.
Command mode: Global configuration
default access­control list <1‐256> meter
Sets the ACL meter configuration to its default values.
Command mode: Global configuration
no access­control list <1‐256> meter
Disables the selected ACL meter.
Command mode: Global configuration
show access­control list <1‐256> meter
Displays current ACL Metering parameters.
Command mode: All