3 Maintenance
3.4.1. Cleaning, complete robot

3.4 Cleaning activities

3.4.1. Cleaning, complete robot
General
The protection class is IP 67, i.e. the manipulator is watertight.
Required equipment
Equipment, etc.
May be used on Foundry
versions only!
Steam cleaner
May be used on Foundry
versions only!
High pressure water cleaner
Vacuum cleaner
Cloth with mild detergent
Do's and don'ts!
The section below specifies some special considerations when cleaning the manipulator.
Always!
Never!
72
Always use cleaning equipment as specified above! Any other cleaning equipment
may shorten the life of paintwork, rust inhibitors, signs, or labels!
Always check that all protective covers are fitted to the robot before cleaning!
Never point the water jet at bearing seals, contacts, and other seals!
Never spray from a distance closer than 0.4 m!
Never remove any covers or other protective devices before cleaning the robot!
Never use any cleaning agents, e.g. compressed air or solvents, other than those
specified above!
Although the manipulator is watertight, avoid spraying connectors and similar items
with a high pressure cleaner!
Art. no. Note
-
Water pressure at nozzle: max. 2,500 kN/
2
m
(25 bar)
Type of nozzle: fan jet, min. 45° spread
Flow: max. 100 litres/min.
Water temperature: max. 80° C
-
Max. water pressure on enclosures: 50 kN/
2
m
(0.5 bar)
Fan jet nozzle should be used, min. 45°
spread
Flow: max. 100 litres/min.
-
May be used on Standard version
3HAC023297-001 Revision: A