ABB M2000 Product Manual page 206

Articulated robot
Hide thumbs Also See for M2000:
Table of Contents

Advertisement

1 Reference information
1.11. Mounting instructions for seals
1.11. Mounting instructions for seals
General
This sections details how to mount different types of seals to the manipulator.
Equipment
Equipment, etc.
Grease
Rotating seals
The procedure below details how to fit rotating seals.
CAUTION!
Please observe the following before commencing any assembly of seals:
Step
24
Art. no.
3HAB 3537-1
Protect the sealing surfaces during transport and mounting.
Keep the seal in its original wrappings or protect it well before actual mounting.
The fitting of seals and gears must be carried out on clean workbenches.
Use a protective sleeve for the sealing lip during mounting, when sliding over threads,
keyways, etc.
Action
1.
Check the seal to ensure that:
the seal is of the correct type (provided with cutting
edge).
there is no damage to the sealing edge (feel with a
fingernail).
2.
Inspect the sealing surface before mounting. If scratches or
damage are found, the seal must be replaced, as it may
result in future leakage.
3.
Lubricate the seal with grease just before fitting. (Not too
early as there is a risk of dirt and foreign particles adhering
to the seal.)
Fill the space between the dust tongue and sealing lip to 2/
3 with grease. The rubber coated external diameter must
also be greased, unless otherwise specified.
4.
Mount the seal correctly with a mounting tool.
Never hammer directly on the seal as this may result in
leakage.
Note
Used to lubricate the seals.
Note
Art. no. is specified in
Equipment
24.
3HAC023297-001 Revision: A
on page