ABB M2000 Product Manual page 156

Articulated robot
Hide thumbs Also See for M2000:
Table of Contents

Advertisement

4 Repair
4.6.6.1. Measuring the gear play, axis 5
Measurement
The procedure below details how to measure the gear play for axis 5.
Step
154
Action
1.
Manually, turn axis 4 90°.
2.
Fit the dial fitting arm and dial
to the manipulator turning disk
as shown in the figure.
Apply the 40 N load as shown.
3.
Remove the load and read
Value 1.
4.
Apply 40 N load as shown.
5.
Remove the load and read
Value 2.
6.
Calculate the gear play value. Gear play value = value 1 - value 2
7.
Determine whether or not the
value is OK.
Note/Illustration
xx0200000457
xx0200000458
OK < 0.18 mm (4.1 arc minutes)
3HAC023297-001 Revision: A