5 Calibration information

5.1. Introduction
General
This chapter includes general information about different calibration methods and details also
procedures that does not require specific calibration equipment.
When the robot system must be recalibrated, it is done according to documentation enclosed
with the calibration tools.
When to calibrate
The system must be calibrated if any of the below occurs.
The resolver values are changed
If resolver values are changed, the robot must be recalibrated using the calibration methods
supplied from ABB. Calibrate the robot carefully with standard calibration. The different
methods are briefly described in section
detailed in separate Calibration manuals.
If the robot has Absolute Accuracy calibration, it is also recommended but not always needed
to be calibrated for new Absolute Accuracy.
The resolver values will change when parts affecting the calibration position are replaced on
the robot, e.g. motors, wrist or part of transmission.
Contents of the revolution counter memory are lost
If the contents of the revolution counter memory are lost, the counters must be updated as
detailed in section
The revolution counters must also be updated after the robot and controller are connected at
the first installation.
The robot is rebuilt
If the robot has been rebuilt, e.g. after a crash or when the robot has been changed for other
reachability, it needs to be recalibrated for new resolver values.
If the robot has Absolute Accuracy calibration, it needs to be calibrated for new Absolute
Accuracy.
References
The article numbers for the Calibration manuals are listed in section
the Product manual (part 2 of 2), reference information. Article numbers for the calibration
tools are also listed in part 2 of the Product manual.
3HAC023297-001 Revision: A
Updating revolution counters
the battery is discharged
a resolver error occurs
the signal between a resolver and measurement board is interrupted
a robot axis is moved with the control system disconnected
5 Calibration information
Calibration methods
on page 164, and further
on page 168. This will occur when:
5.1. Introduction
Document references
in
163