CONFIGURE

configure module t1 alarms hierarchy

This command enables and disables the hierarchy for displaying RLOS and RLOF on a T1 link.
Users may select an individual T1 or a range of T1s when using this command.
syntax:
alarms hierarchy
example:
SR/configure/module/t1 1/3> alarms hierarchy
To view the alarms hierarchy once it has been set, use the show module configuration
command. The display will indicate either "True" or "False." When set to TRUE, a Loss of Signal
will only assert RLOS alarm. When set to FALSE, a Loss of Signal will assert both RLOS and
RLOF alarms.
configure module t1 alarms thresholds
applies to:
T1 module
configure module t1 alarms thresholds
This command accesses next-level commands for configuring alarm thresholds.
If a user-defined threshold is exceeded, the system reports an alarm. These alarms indicate
the possible deterioration of an associated T1link.
syntax:
thresholds
example:
SR/configure/module/t1 1/3/alarms> thresholds
configure module t1 alarms thresholds user