1.2 SCANNING

SC107: Lamp regulator malfunction
- Definition - [B]
Detects lamp regulator malfunctions by monitoring the signal for both the
exposure lamp on and off conditions.
<Possible causes>
Lamp regulator defective
Exposure lamp open
Optics thermoswitch open
Scanner control board defective or poor connection
SC120: Scanner HP sensor abnormal - Stays off
- Definition - [B]
The scanner home position sensor does not detect the on condition
during scanner initialization.
<Possible causes>
Scanner HP sensor defective
Scanner motor defective or poor connection
Scanner drive board defective or poor connection
Scanner control board defective or poor connection
Loose Allen screw on scanner drive pulleys
DC power supply board defective (FU803) or (FU805)
SC121: Scanner HP sensor abnormal - Stays on
- Definition - [B]
The scanner home position sensor does not detect the off condition
during scanner initialization.
<Possible causes>
Scanner HP sensor defective
Scanner motor defective or poor connection
Scanner drive board defective or poor connection
Scanner control board defective or poor connection
Loose Allen screw on scanner drive pulleys
DC power supply board defective (FU803)