4.7 ORIGINAL WIDTH SENSOR AND ORIGINAL LENGTH
SENSOR (2) REPLACEMENT
1. Turn off the main switch and unplug the machine.
2. Remove the exposure glass. (See Exposure Glass Removal.)
3. Remove the APS sensor cover [A] (7 screws).
4. Replace the original width sensor [B] or the original length sensor (2) [C]
(1 screw, 1 connector each).
FSM
[B]
5-23
[A]
[C]
A109