Rev. 3/20/96

4.2.3 Route the PTL harness and attach the belt cleaning unit

[B]
[E]
NOTE: Machines manufactured before Serial Number A3514090001 are
not equipped with the PTL relay harness. Therefore perform the
following steps. If the harnesses are already installed, skip to
step 4.
1. Route the white connector end [A] of the PTL harness [B] from the upper
rear right side of machine through to the rear as shown in the diagram (8
clamps).
2. Run the PTL relay harness [C] (3 clamps) down the rear side and connect
it to the connector [D] and the PTL harness [E].
3. Route the PTL harness [F] through the front side of the machine (8
clamps).
4. Reinstall the belt cleaning unit and connect it to the PTL harness [G].
5. Reinstall the transfer belt stay [H] (5 screws and 3 connectors).
6. Reinstall the toner collection duct (1 hook).
NOTE: Connect the connector of the PTL unit before reattaching the
transfer belt stay. Also, disconnect it after removing the transfer
belt stay.
After reinstalling the transfer belt stay, secure the PTL harness
with the 2 clamps [I] on the transfer belt stay.
A109
[A]
[H]
[I]
[C]
[D]
6
[G]
Controller Interface Kit Type-A
[F]