Table of Contents

Advertisement

SC558: Zero cross signal abnormal
- Definition - [A]
Zero cross signals are not detected within a certain period.
<Possible causes>
Main control board defective

1.9 COMMUNICATION

SC600: Communication error between main control and
panel boards
- Definition - [B]
Main CPU cannot communicate with the operation panel CPU properly.
<Possible causes>
Poor connection between the main control board and operation panel
board
Main board defective
Operation panel defective
SC601: Communication error between main control and scanner
control boards
- Definition - [B]
Main CPU cannot communicate with the scanner control CPU properly.
<Possible causes>
Poor connection between the main control board and scanner control
board (optical fiber cable)
Optical fiber cable defective
Main control board defective
Scanner control board defective
DC power supply board defective (No dc 5V input to scanner control
board)