3. SERVICE TABLES
3.1 TEST POINT
NUMBER
TP100
TP101
TP102
TP103
3.2 LEDs
NUMBER
LED100
Lights when the inlet sensor is activated.
LED101
Lights when the entry sensor is activated.
Lights when the sorter motor speed is corrected in speed
LED102
adjustment
3.3 DIP SWITCH
DPS100
1
2
3
1
0
0
1
0
0
1
0
0
0
1
0
0
1
0
NOTE: DIP switches should all be OFF in normal mode.
3.4 VARIABLE RESISTORS
NUMBER
VR100
Adjusts slow speed of the motor.
VR101
Adjusts high speed of the motor.
FSM
FUNCTION
Factory Use
24 V
5 V
0 V (GND)
FUNCTION
4
1
Free run without paper.
0
Free run with paper.
(Paper feeding check)
0
Adjusts the motor speed in Slow Speed
0
mode by VR101.
Adjust the motor speed in High Speed mode
1
by VR100.
FUNCTION
8-13
Rev. 7/94
FUNCTION
A109