Machine Level; Date/Time Setting; Sp Codes - Ricoh B064 SERIES Service Manual

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

MAIN MACHINE (B064 SERIES/B140 SERIES/B246 SERIES/D052 SERIES)

Machine Level

1. Set a stand [A] at each corner of the
machine.
2. Place a level on the exposure glass
and use a wrench to turn each nut [B]
and level the machine to ±5 mm of the
horizontal.
3. Check the machine operation. With the
customer, determine the best place to
attach the cleaning reminder decal.

Date/Time Setting

Use the User Tools menu to set the current date and time.
• On the operation panel, press the User Tools key.
• On the touch-panel, press "System Settings".
• Press the "Timer Setting" tab.
• Press "Set Date" the enter the date.
• Press "Set Time" to enter the time.

SP Codes

SP5812-001~002
SP5841-001
SP5853
SP7825 (B064 Series Only)
B064 Series/B140 Series
/B246 Series/D052 Series
CÓPIA NÃO CONTROLADA
Service Telephone
Number Settings
Supply Name Setting –
Toner Name Setting:
Black
Stamp Data Download
Total Counter Reset
1-22
CÓPIA NÃO CONTROLADA
Rev. 04/2008
[A]
Execute this SP and enter the
contact numbers of the custom
engineer. These are the
numbers displayed when a
service call is issued.
This name appears when the
user presses the Inquiry on the
User Tools screen.
Do SP 5853 to copy stamp
data to the hard disk, then turn
the power off/on.
Execute after installation and
after making all test copies to
reset the electronic counter
total.
[B]