Ricoh B064 SERIES Service Manual page 710

Hide thumbs Also See for B064 SERIES:
Table of Contents

Advertisement

SERVICE PROGRAM MODE TABLES
2004
Photo Mode
001
Main Scan MTF Level
002
Sub Scan MTF Level
003
Main Scan MTF Strength
004
Sub Scan MTF Strength
005
Smoothing Level
006
Gamma Selection
007
Dither Pattern
008
Density Level 7 Light:
Brightness
009
Density Level 7 Light:
Contrast
010
Density Level 7 Light:
Threshold
011
Density Level 6:
Brightness
012
Density Level 6:
Contrast
013
Density Level 6:
Threshold
014
Density Level 5:
Brightness
015
Density Level 5:
Contrast
016
Density Level 5:
Threshold
017
Density Level 4
Intermediate: Brightness
018
Density Level 4
Intermediate: Contrast
B064 Series/B140 Series
/B246 Series/D052 Series
CÓPIA NÃO CONTROLADA
Sets the MTF coefficient for the main scan
direction.
[0x00~0xFF/0x01]
Sets the MTF coefficient for the sub scan
direction.
[0x00~0xFF/0x01]
Sets the MTF strength for the main scan
direction.
[0~0x07/0x01]
Sets the MTF strength for the sub scan
direction.
[0~0x07/0x01]
Sets the smoothing coefficient.
[0~0x07/0x01]
Selects the gamma setting.
[0x00~0x06/0x01]
0:Normal
1:Smooth
2:Distinct
3:Sharp
4:Text
5:Photo.
[0x01/0x0x]
The following SPs adjust the image density
(brightness, contrast, and thresholds) for each
image density level (from 7 to 1) for Photo
mode when using the delivery scanner mode.
The settings are reflected in the gamma table.
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]
[1~255/1]